Helita lightning protection software full#Upon completion of the inspection, we shall provide a full detailed report and certificate to suit the system installation standard & condition. Ltd provide a comprehensive inspection report and which outlines any defects and additional work required. Upon completion of the inspection, Rainey and Co. This will ensure the property remains fully protected against lighting strikes, fit for purpose and meets building insurance requirements. In accordance with ISEN 62305 ‘Protection Against Lightning’. We recommend all systems should be visually inspected, tested and maintained on an annual basis. team of specialists offer a comprehensive plan prevention and maintanenance service for all lightning protection systems. We also offer a 10 year warranty for all new installations, providing that the system is tested and maintained by ourselves on an annual basis. Our installed systems give this energy a safe and low impedance path to earth. The installation of our lightning protection and earthing systems will prevent any potential damage that can be caused by lightning strikes. Our fully trained personnel have access to the highest quality resources, materials and equipment required to work on any scale of lightning protection and earthing systems project. We boast Ireland’s most experienced lightning protection installation workforce, having worked for over 30 years on large and small scale projects across the region. Lightning protection systems must only be installed by fully registered contractors, such as Rainey and Co. Down conductors, each terminating in an earth pit location with a collective Ohms reading of 10 Ohms or less. Design of co-ordinated lightning protection, surge protection and earthing systems to Drafting services, including CAD drawings with full systems layouts and details Tender documentation, recommendations and costing for protection systems to ISEN 6205 standard. The main advantage of utilising a Helita Pulsar lightning protection system is that it does not require a faraday cage system of roof tapes and down conductors but only requires an air terminal and the installation of 2 No. Recommendations and costings for complete protection systems to ensure compliance with ISEN 62035 standards.Inspection and testing of lightning protection systems, earthing systems, bonding arrangements and surge protection.Review of existing documentation, designs and drawings.Consideration of explosive areas (ATEX) in design to avoid ignition sources.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |